The underground water in this site has a moderate corrosive effect on the structural components. It may cause slight corrosion to the steel reinforcement in the reinforced concrete structures and weak corrosion to the steel structures. The soil in this site has a moderate corrosive effect on building materials. To prevent corrosion, it is recommended to follow the relevant regulations and requirements of the national standard "Design Code for Anticorrosion of Industrial Buildings" (GE50046-2018). In addition, it is also necessary to comply with the requirements of Section 3.4 of the provincial standard "Technical Regulations for Prestressed Concrete Pipe Pile Foundation by Pre-Tensioning Method" (DBJ13-86-2007), including the thickness of joint welds and end plates.

10.	本场地地下水对砣结构具有徼腐蚀性.对钢籍吐结构中的钢筋具有微腐蚀性,对钢结构具有弱腐蚀性。场地土对建筑材料具徼腐蚀性。建议依据国标《工业建筑防腐蚀设计规范》(GE50046-2018 )的有关规定和要求进行防腐处理外,还应按省标《先张法预应力混凝士管桩基础技术规程》DBJ13-86-2007第.3.4条的规定,满足接头焊缝、端头板厚度等要求。改写这段话查重率低于20%