以下是一个可能的 PowerMeter 类实现,用于与仪表设备进行串口通信并获取数据:

using System;
using System.IO.Ports;
using System.Threading;

public class PowerMeter
{
    private SerialPort _serialPort;
    private bool _isOpen;

    public PowerMeter()
    {
        _serialPort = new SerialPort();
        _serialPort.BaudRate = 9600;
        _serialPort.Parity = Parity.None;
        _serialPort.DataBits = 8;
        _serialPort.StopBits = StopBits.One;
        _serialPort.Handshake = Handshake.None;
        _serialPort.ReadTimeout = 500;
        _serialPort.WriteTimeout = 500;
    }

    public bool Open(string portName)
    {
        if (_isOpen)
        {
            return true;
        }

        _serialPort.PortName = portName;
        try
        {
            _serialPort.Open();
        }
        catch (Exception)
        {
            return false;
        }

        _isOpen = true;

        // 发送握手命令
        if (!SendCommand("?"))
        {
            Close();
            return false;
        }

        // 等待握手成功
        string response = ReadResponse();
        if (response != ".")
        {
            Close();
            return false;
        }

        // 发送获取数据命令
        if (!SendCommand("T", 24))
        {
            Close();
            return false;
        }

        // 等待获取完整数据
        response = ReadResponse();
        while (response.Length < 25 || !response.StartsWith("A") && !response.StartsWith("B")
            && !response.StartsWith("C") && !response.StartsWith("D") && !response.StartsWith("E")
            && !response.StartsWith("F") && !response.StartsWith("G") || !response.EndsWith("V"))
        {
            if (response.Length > 0 && response[response.Length - 1] == 'T')
            {
                // 发送补发命令
                if (!SendCommand("T", 1))
                {
                    Close();
                    return false;
                }
            }
            else
            {
                // 等待一段时间再读取
                Thread.Sleep(2);
                response += ReadResponse();
            }
        }

        // 关闭串口
        Close();

        return true;
    }

    public void Close()
    {
        if (_isOpen)
        {
            _serialPort.Close();
            _isOpen = false;
        }
    }

    private bool SendCommand(string command, int repeatCount = 1)
    {
        for (int i = 0; i < repeatCount; i++)
        {
            try
            {
                _serialPort.Write(command);
                Thread.Sleep(2);
            }
            catch (Exception)
            {
                return false;
            }
        }
        return true;
    }

    private string ReadResponse()
    {
        try
        {
            return _serialPort.ReadExisting();
        }
        catch (Exception)
        {
            return "";
        }
    }
}

该类使用 SerialPort 类实现串口通信,其中 Open 方法用于打开串口并开始发送命令,Close 方法用于关闭串口,SendCommand 方法用于发送命令并等待一段时间,ReadResponse 方法用于读取串口返回的数据。

Open 方法中,首先发送握手命令,检查返回的数据是否为 . ,如果不是则认为握手失败,关闭串口并返回 false。然后发送获取数据命令,如果发送失败则关闭串口并返回 false。接着等待串口返回的数据,如果返回的数据长度小于 25 或者开头不是 A/B/C/D/E/F/G 或者结尾不是 V,则说明返回的数据不完整,需要等待一段时间再次读取,如果读取到的数据中有 T,则说明数据不完整,需要发送补发命令,如果补发命令发送失败,则关闭串口并返回 false。如果读取到的数据是完整的,则关闭串口并返回 true。如果在任何一个步骤中发生了错误,则直接关闭串口并返回 false

注意: 这个类的实现仅供参考,具体的实现可能会因为硬件、协议等方面的不同而有所区别。

C# PowerMeter 类:串口通信获取仪表数据

原文地址: https://www.cveoy.top/t/topic/mEZ6 著作权归作者所有。请勿转载和采集!

免费AI点我,无需注册和登录