本文针对研究区域内不同用水行为下及排水片区末端的污水中34S的变化规律开展了实验研究。得出以下结论:根据不同用水行为下34S变化规律分析除餐厨行为引起了6469的增幅外洗漱、淋浴、舆洗室及餐具清洗行为下34S相对自来水的变化比例均值范围为-1437 ~ 562。故34S在整体范围上受不同用水行为影响较小其在各类用水行为下指标稳定性较好。2根据排水片区末端的污水中34S的变化规律分析3
This article presents an experimental study on the variation of δ34S in sewage at the end of drainage areas under different water use behaviors. The following conclusions were drawn:
(1) Based on the analysis of the variation of δ34S under different water use behaviors, except for the kitchen behavior that caused a 64.69% increase, the relative change of δ34S compared to tap water under washing, showering, toilet flushing, and tableware cleaning behaviors was in the range of -14.37% to 5.62%. Therefore, δ34S is less affected by different water use behaviors in the overall range, and its stability is good under various water use behaviors.
(2) Based on the analysis of the variation of δ34S in sewage at the end of drainage areas, the fluctuation amplitude of δ34S in sewage at the end of drainage areas relative to the baseline level of tap water is small, and its relative change compared to tap water has an average value of 25.99%. The variation of δ34S with time is small and stable, and the daily fluctuation pattern has a certain reproducibility.
(3) Combining with uncertainty evaluation, δ34S has good stability under different water use behaviors of drainage households and in sewage at the end of drainage areas. Therefore, δ34S is suitable as a water quality characteristic factor for pipeline diagnosis
原文地址: https://www.cveoy.top/t/topic/eHT4 著作权归作者所有。请勿转载和采集!