According to previous studies, a shorter diameter of the ceramic reflector results in a higher absorption efficiency of the crystal [15]. Therefore, while ensuring the cooling effect of the crystal, we have minimized the inner diameter of the reflector to 8mm and designed the inner diameter of the glass tube to be 6mm. As a result, the distance between the LD emitting surface and the crystal axis center is only 6mm, which allows for a higher pumping power density in the crystal rod, facilitating high-power laser output